ODH1000 Conventional fire alarm control panel, alarm control panel, fire alarm panel

Price: 1
Brand Name:
Model Number:
Country/Region: China
Post Date: Jul 16,2011

Product Description: ODH1000 Conventional fire alarm control panel, alarm control panel, fire alarm panel


Key words: Fire alarm Control Panel,conventional fire alarm control panel,  fire alarm panel, fire alarm, FACP, fire alarm system, fire-fighting, fire panel, fire alarm controller, fire alarm control unit Features 1) 4/8/16 Style B (Class B) Initiating Device Circuits (IDCs).    - All zones accept two-wire smoke detectors and any normally-open contact devices.    - Zones 1 4/8/16 configured as general alarm zones.2) All circuits are power-limited and supervised, meeting the latest ULC requirements using      fuseless technology.3) Two built-in, Style Y (Class B) Notification Appliance (Signal) Circuits (NACs). 4) NACs may be programmed:    - Silenceable    - Non-Silenceable    - Auto-Silence (program 5 to 20 minutes)5) 1.25 amps of NAC power6) 3.0 amps of total system power7) Alarm, Trouble and Supervisory, Form-C relays standard.8) 24-volt operation9) Resettable four-wire smoke detector power @ 500 mA10)  Non-resettable power @ 500 mA11) Integral battery charger capable of charging up to 18 AH batteries (batteries over 4 AH require      use of the external battery backbox, or ULC listed equivalent).12) One-man walk-test programmable for silent or audible test13) Disable/Enable control per IDC14) Reverse polarity protection15) Control buttons:      - Mode      - Test      - ACK (Acknowledge) Alarm Silence      - Reset16) Meet UL864, EN-54 standard.17) LED indicators:      - AC Power (green & yellow LED)      - Fire Alarm (red LED)      - Trouble (yellow LED)      - Supervisory (yellow LED)      - Signal Silence (yellow LED)      - Battery Power (green & yellow LED)      - Zone Disable (yellow LED)      - NAC Fault (yellow LED)      - NAC Disable (yellow LED)      - 4/8/16 Zone Alarm (one for each zone) (red LED)      - 4/8/16 Zone Trouble (one for each zone) (yellow LED)      - Earth Fault (on circuit board)      - Battery Fault (on circuit board)      - Charger Fault (on circuit board) Specifications AC Power: AC220V±10% 50Hz, 2.0 amps, minimum 14 AWG wire (2.0 mm²) with 600-volt                   insulation.Battery: Sealed lead-acid batteries only, Maximum charging circuit: 27.6VDC @ 0.8 amp for              normal flat charge, Maximum battery charger capacity: 18AH battery              NOTE:  Two 4AH batteries can be housed in the cabinet.uire                            separate & nbp battery box.Total 24 V system power: 3.0 amps          Notification appliance (signal) power: 2.5 ampsMaximum current per NAC: 1.25 amps (expandable to 2.5 amps)Auxiliary Outputs:   - Resettable four-wire smoke detector power @ 500 mA                             - Non-resettable power @ 500 mA                             - Integral Form-C Alarm, Trouble and Supervisory relays, rated at: 2.0 amps                                @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive).NOTE: Total current for auxiliary power outputs and two NACs must not exceed 3.0 amps.Dimensions: 320×260×80mm (length × width × depth)Using Environment: Temperature: 10°C~+50°C  Related Humidity: ≤95% (40±2°C) Orena Sales and ServiceShenzhen Orena Photonic Technology Co., LtdOrena Bldg, Zhong'an Industrial Park, Longjing Road 691#, Nanshan District, Shenzhen, 518055, ChinaTel: 86.755.2678.7499       Fax: 86.755.2678.7499

Supplier Details:

Shenzhen Orena Photonic Technology Co., Ltd.

Sales:Mr. Barry Zhang

Contact Phone:86-755-26787499

Main Products:Fire Alarm Control Panel

Business type:Manufacturer

SPONSOR AD

User Reviews: ODH1000 Conventional fire alarm control panel, alarm control panel, fire alarm panel