14 Zone conventional fire alarm panel

Price: US $1 - 100 / Set
Brand Name: ASENWARE
Model Number: AW-CFP2166-14
Country/Region: China
Post Date: Jul 16,2011

Product Description: 14 Zone conventional fire alarm panel


Introduction: 
    AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.It is modularized design, the panel can expend from 1 zone to 16 zones easily.It has 2 level control mode by a lockIt has TEST/ALARM OUTPUT function, when TEST is enable, the user can test all buttons and won’t let the sounders be active.It has SOUNDERS OUTPUT option, if one zone is fire alarm, all other zones sounders can be active or not.It has 27VDC power supply output.It has FIRE signal output.It has 2 general sounders output, any zone fire alarm will let the 2 general sounders be active.Each zone has 1 circuit detectors input and 2 SOUNDERs output.Each zone can test zone fault, sounder fault and show on the front panel.It has RESET button to reset the panel.It has SILENCE button to stop BUZZER and SOUNDERS.It has EVACUATE button to start a manual fire alarm immediately.It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.It uses plug-in sockets and plugs, convenience for maintenance.It is economic, user-friendly and easy maintenance.
 Parameters:ITEM4 Zone panel8 Zone panel16 Zone panelModel No.AW-CFP2166-04AW-CFP2166-08AW-CFP2166-16Power specificationMains supply voltage100-240VACInternal power supply27.2VDCTotal output current limited1.6A @ 240VAC3A @ 240VAC5A @ 240VACMain supply monitor for faultYesBattery protection for low voltageYesBatteries (default configuration)12V2AH*212V3.2AH*212V7AH*2Detector circuit specificationNumber of circuit1-41-81-16Line fault monitor for open circuitYesLine fault monitor for short circuitYesLine fault monitor for detector removalYes, if End of Line Monitor Unit fitted in place of End of Line ResistorEnd of Line device6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)Detector continuity diodesSilicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault)Call point resistor value470 to 680 Ω, 0.225 or 0.5 wattMaximum number of smoke/heat detectors per zone20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts.Maximum number of manual call points per zoneNo limitSounder circuit specificationNumber of general circuits2Number of each zone2End of line resistor value6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)Line fault monitor for open circuitYesLine fault monitor for short circuitYesOutputs fused AT400mAMaximum number of bells @ 25mA of each zone16(These quantities are examples only. Divide 400 by the consumption of each sounder/bell in mA to calculate the maximum number.)Maximum number of bells @ 20mA of each zone20FusesBattery fuse1.5A F 20mm3A F 20mm5A F 20mmSounder outputs500mA F 20mm  Fire outputOutput typeIntended to drive external 24V relaysMaximum current30mA(Relay resistance must be greater than 800Ω and relay must have “ back EMF” diode fitted).Connection blockLargest acceptable conductor size2.5mm2Smallest acceptable conductor size0.75mm2Size and weightDimensions(mm)395X388X124395X502X124362X565X124Weight (without batteries)5kg7kg8kgWeight (with batteries)6.8kg9.6kg12.5kg

Supplier Details:

Shenzhen Asenware Test & Control Technology Co., Ltd.

Sales:Mr. Strong Wang

Contact Phone:86-755-27663815

Main Products:Fire Alarm Control Panel

Business type:Manufacturer, Trading Company, Distributor/Wholesaler

SPONSOR AD

User Reviews: 14 Zone conventional fire alarm panel